B.3 Parameter Table
422 YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
■ o2: Digital Operator Keypad Functions
o1-20
(575H)
Traction Sheave Diameter
Sets the traction sheave diameter for display unit calculations.
Default: 400 mm
<38>
Min: 100 mm
Max: 2000 mm
<38>
251
o1-21
(576H)
Roping Ratio
Sets the roping ratio.
1: 1:1
2: 1:2
3: 1:3
4: 1:4
Default: 2
Min: 1
Max: 4
251
o1-22
(577H)
Mechanical Gear Ratio
Sets the ratio of the gear installed for display unit calculations.
Default:
<5>
Min: 0.10
Max:
<46>
252
o1-23
(174H)
<45>
HBB Non Display Select Shows or hides the HBB command on the digital operator while the safety signal is being input.
0: Shows HBB
1: Hide HBB
Default: 0
Min: 0
Max: 1
252
<5> Default setting is determined by the control mode (A1-02).
<20> This parameter appears when the drive displays user-set units (o1-03 = 3).
<21> The control mode determines the selections available. In V/f Control, only settings 1 through 3 are permitted.
<38> Default setting and setting range changes when inches are selected for the length units (o1-12 = 1). The setting range becomes 3.70 to 78.00
inches, and the default becomes 15.70 inches.
<44> Available in drive software versions PRG: 7017 or later.
<45> Available in drive software versions PRG: 7200 or later.
<46> The setting range changes depending on drive software versions.
PRG: 7017 or earlier: 0.10 to 50.00
PRG: 7200 or later: 0.10 to 100.00
No. (Addr.) Name Description Setting Page
o2-01
(505H)
<1> Parameter setting value is not reset to the default value when the drive is initialized.
LO/RE Key Function Selection
0: Disabled
1: Enabled. LO/RE key switches between LOCAL and REMOTE operation.
Default: 0
Min: 0
Max: 1
252
o2-02
(506H)
STOP Key Function Selection
0: Disabled. STOP key is disabled in REMOTE operation.
1: Enabled. STOP key is always enabled.
Default: 0
Min: 0
Max: 1
252
o2-03
(507H)
User Parameter Default Value 0: No change.
1: Set defaults. Saves parameter settings as default values for a User Initialization.
2: Clear all. Clears the default settings that have been saved for a User Initialization.
Default: 0
Min: 0
Max: 2
253
o2-04
(508H)
<1>
Drive Model Selection
Enter the drive model. Setting required only if installing a new control board.
Default: Determined by
drive capacity
Min: –
Max: –
253
o2-05
(509H)
Speed Reference Setting Method
Selection
0: ENTER key must be pressed to enter a speed reference.
1: ENTER key is not required. The speed reference can be adjusted using the up and down
arrow keys only.
Default: 0
Min: 0
Max: 1
253
o2-06
(50AH)
Operation Selection when Digital
Operator is Disconnected
0: The drive continues operating if the digital operator is disconnected.
1: A fault is triggered (oPr) and the motor coasts to stop.
Default: 0
Min: 0
Max: 1
254
o2-09
(50DH)
Reserved – – –
No. (Addr.) Name Description Setting Page
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes