4.3 The Drive and Programming Modes
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual 103
Start-Up Programming &
Operation
4
■ Setup Group Parameters
Table 4.4 lists parameters available by default in the Setup Group.
If a parameter that needs to be edited is not displayed in the Setup Group, access the parameter through the Programming
Mode.
Table 4.4 Setup Group Parameters
Note: Parameter availability depends on the control mode set in A1-02; some parameters listed above may not be accessible in all
control modes.
◆ Switching Between LOCAL and REMOTE
LOCAL mode is when the drive is set to accept the Up/Down command from the digital operator keypad. REMOTE
mode is when the drive is set to accept the Up/Down command from an external device (via the input terminals or serial
communications, etc.).
Switch the operation between LOCAL and REMOTE using the LO/RE key on the digital operator or via a digital input.
This key is disabled with default settings, but can be enabled by setting parameter o2-01 to 1.
Note: 1. After selecting LOCAL, the LO/RE light will remain lit.
2. The drive will not allow the user to switch between LOCAL and REMOTE during run.
■ Using the LO/RE Key on the Digital Operator
Parameter Name Parameter Name
A1-02 Control Method Selection E1-01 Input Voltage Setting
b1-01 Speed Reference Selection E1-04 Maximum Output Frequency
C1-01 Acceleration Ramp 1 E1-05 Maximum Voltage
C1-02 Deceleration Ramp 1 E1-06 Base Frequency
d1-01 Speed Reference 1 E1-09 Minimum Output Frequency
d1-02 Speed Reference 2 E1-13 Base Voltage
d1-03 Speed Reference 3 E2-01 Motor Rated Current
d1-04 Speed Reference 4 E2-11 Motor Rated Output
d1-26 Leveling Speed L1-01 Motor Overload Protection Selection
Step Display/Result
1. Turn on the power to the drive. The initial display appears.
2.
Press . The LO/RE light will light up. The drive is now in LOCAL.
To set the drive for REMOTE operation, press again.
- MODE -
U1-01= 0.00%
U1-02= 0.00%
U1-03= 0.00A
DRV
Speed Ref(A1/A2)
Rdy
RSEQ
RREF
FWD FWD/REV
LO
RE
F2F1
ESC
RUN STOP
ENTERRESET
ALM
DIGITAL OPERATOR JVOP-180
- MODE -
U1-01= 0.00%
U1-02= 0.00%
U1-03= 0.00A
DRV
Speed Ref (OPR)
Rdy
LSEQ
LREF
FWD
SIEP_C710616_38F_5_0.book 103 ページ 2015年11月9日 月曜日 午後3時36分