442 YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
B.6 Defaults and Setting Ranges by Display Unit Selection (o1-03)
B.6
Defaults and Setting Ranges by Display Unit Selection (o1-03)
Table B.7 shows parameters, default settings, and setting ranges that change according to parameter o1-03, Display Unit
Selection.
Table B.7 Defaults and Setting Ranges by Display Unit Selection (o1-03)
No.
<1> Automatically calculated according to the values set to o1-20, o1-21, o1-22, and E2-/E5- parameters.
<2> Automatically calculated according to the values set to the E2-/E5- parameters.
Name
o1-03 (Digital Operator Display Unit Selection)
Default
0
(0.01 Hz)
1
(0.01%)
2
(r/min)
3
(User-set)
4
(Elevator
units 1)
5
(Elevator
units 2)
6
(Elevator
units 3)
C1-01 Acceleration Ramp 1
0.00 to 600.00 s
0.00 to
<1>
m/s
2
0.00 to
<1>
ft/s
2
1.50 s
C1-02 Deceleration Ramp 1
C1-03 Acceleration Ramp 2
C1-04 Deceleration Ramp 2
C1-05 Acceleration Ramp 3
C1-06 Deceleration Ramp 3
C1-07 Acceleration Ramp 4
C1-08 Deceleration Ramp 4
C1-09 Fast Stop Time
C1-15 Inspection Run Deceleration Ramp 0.00 s
C2-01 Jerk at Accel Start
0.00 to 10.00 s
0.00 to
<1>
m/s
3
0.00 to
<1>
ft/s
3
0.50 s
C2-02 Jerk at Accel End
C2-03 Jerk at Decel Start
C2-04 Jerk at Decel End
C2-05 Jerk below leveling speed
C1-11 Accel/Decel Switching Speed
0.00 to
[E1-04] Hz
0.00 to
100.00%
0.00 to
<2>
r/min
User define 0.00 to
<1>
m/s
0.00 to
<1>
ft/min
0.0%
d1-01 Speed Reference 1
0.00%
d1-02 Speed Reference 2
d1-03 Speed Reference 3
d1-04 Speed Reference 4
d1-05 Speed Reference 5
d1-06 Speed Reference 6
d1-07 Speed Reference 7
d1-08 Speed Reference 8
d1-19 Nominal Speed 100.0%
d1-20 Intermediate Speed 1
0.00%
d1-21 Intermediate Speed 2
d1-22 Intermediate Speed 3
d1-23 Releveling Speed
d1-24 Inspection Operation Speed 50.00%
d1-25 Rescue Operation Speed 10.00%
d1-26 Leveling Speed 8.00%
SIEP_C710616_38F_5_0.book 442 ージ 015年11月9日 月曜日 午後3時36分