B.5 Defaults by Drive Model Selection (o2-04)
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual 441
Parameter List
B
Table B.6 600 V Class Drives Default Settings by Drive Capacity
No. Name Unit Default Settings
Model CIMR-LU 50003 50004 50006 50010 50013 50017 50022 50027 50032
o2-04 Drive Model Selection Hex. C4 C5 C7 C9 CA CC CD CE CF
E2-11 Motor Rated Output HP 2 3 5 7.5 10 15 20 25 30
C5-17 Motor Inertia
kgm
2
0.0068 0.0088 0.0158 0.026 0.037 0.053 0.076 0.138 0.165
C6-03Carrier Frequency kHz888888888
E2-01
(E4-01)
Motor Rated Current A 2.7 3.9 6.1 9 11 17 22 27 32
E2-02
(E4-02)
Motor Rated Slip Hz 2.5 3.0 2.7 1.5 1.3 1.7 1.6 1.67 1.7
E2-03
(E4-03)
Motor No-Load Current A 0.8 1.2 1.8 2.7 3.3 5.1 6.6 8.1 9.6
E2-05
(E4-05)
Motor Line-to-Line Resistance Ω 13.72 8.825 4.936 2.601 1.446 1.171 0.896 0.658 0.516
E2-06
(E4-06)
Motor Leakage Inductance % 18.3 18.7 19.3 18.2 15.5 19.6 17.2 20.1 23.5
E2-10 Motor Iron Loss for Torque Compensation W 53 77 130 193 263 385 440 508 586
E3-08 Motor 2 Mid Output Frequency Voltage V 43.1 40.3 40.3 40.3 40.3 40.3 40.3 40.3 40.3
E3-10 Motor 2 Minimum Output Frequency Voltage V 25.9 20.1 20.1 20.1 20.1 20.1 20.1 20.1 20.1
E5-02Motor Rated Power HP 2 3 5 7.51015202530
E5-03 Motor Rated Current A 2.6 3.1 4.7 7.4 9.4 12.8 16.5 20.3 24.0
E5-05 Motor Stator Resistance Ω 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
E5-06 Motor d-Axis Inductance mH 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
E5-07 Motor q-Axis Inductance mH 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
E5-09 Motor Induction Voltage Constant 1 mV/(rad/sec) 0 0 0 0 0 0 0 0 0
L8-02 Overheat Alarm Level °C 110 110 110 115 120 120 115 115 110
L8-06 Input Phase Loss Detection Level % 23 14 15 24 15 21 15 19 11
L8-35Installation Method Selection 222222222
n5-02 Motor Acceleration Time s 0.166 0.145 0.154 0.168 0.175 0.265 0.244 0.317 0.355
n9-60 A/D Conversion Start Delay μsec 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0
No. Name Unit Default Settings
Model CIMR-LU 50041 50052 50062 50077 50099 50130 50172 50200
o2-04 Drive Model Selection Hex. D1 D2 D3 D4 D5 D6 D7 D9
E2-11 Motor Rated Output HP 40 50 60 75 100 125 150 250
C5-17 Motor Inertia
kgm
2
0.220 0.273 0.333 0.49 0.90 1.10 1.90 3.30
C6-03Carrier Frequency kHz88853333
E2-01
(E4-01)
Motor Rated Current A 4152627799130172200
E2-02
(E4-02)
Motor Rated Slip Hz 1.8 1.33 1.6 1.46 1.39 1.39 1.4 1.35
E2-03
(E4-03)
Motor No-Load Current A 12.3 15.6 18.8 23.1 29.7 37.5 43.2 57.6
E2-05
(E4-05)
Motor Line-to-Line Resistance Ω 0.438 0.267 0.210 0.150 0.099 0.079 0.060 0.037
E2-06
(E4-06)
Motor Leakage Inductance % 20.7 18.8 19.9 20.0 20.0 20.0 20.0 20.0
E2-10 Motor Iron Loss for Torque Compensation W 750 925 1125 1260 1600 2150 2150 2850
E3-08 Motor 2 Mid Output Frequency Voltage V 40.3 40.3 40.3 34.5 34.5 34.5 34.5 34.5
E3-10 Motor 2 Minimum Output Frequency Voltage V 20.1 20.1 20.1 17.3 17.3 17.3 17.3 17.3
E5-02 Motor Rated Power HP 40 50 60 75 100 125 150 250
E5-03 Motor Rated Current A 30.8 39.0 46.5 57.8 74.3 97.5 129.0 150.0
E5-05 Motor Stator Resistance Ω 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
E5-06 Motor d-Axis Inductance mH 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
E5-07 Motor q-Axis Inductance mH 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
E5-09 Motor Induction Voltage Constant 1 mV/(rad/sec) 0 0 0 0 0 0 0 0
L8-02 Overheat Alarm Level °C 110 110 110 110 110 110 110 110
L8-06 Input Phase Loss Detection Level % 14 11 13 17 12 16 15 18
L8-35 Installation Method Selection 2 2 2 2 2 0 0 0
n5-02 Motor Acceleration Time s 0.323 0.320 0.387 0.317 0.533 0.592 0.646 0.777
n9-60 A/D Conversion Start Delay μsec 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0
SIEP_C710616_38F_5_0.book 441 ージ 015年11月9日 月曜日 午後3時36分