B.5 Defaults by Drive Model Selection (o2-04)
440 YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
No. Name Unit Default Settings
– Model CIMR-LU – 40039 40045 40060 40075 40091 40112 40150
o2-04 Drive Model Selection Hex. 9E 9F A1 A2 A3 A4 A5
E2-11 Motor Rated Output HP 25 30 40 50 60 75 100
C5-17 Motor Inertia
kgm
2
0.138 0.165 0.220 0.273 0.333 0.49 0.90
C6-03Carrier Frequency kHz8885555
E2-01
(E4-01)
Motor Rated Current A 32.9 38.6 52.3 65.6 79.7 95 130
E2-02
(E4-02)
Motor Rated Slip Hz 1.67 1.7 1.8 1.33 1.6 1.46 1.39
E2-03
(E4-03)
Motor No-Load Current A 7.8 9.2 10.9 19.1 22 24 36
E2-05
(E4-05)
Motor Line-to-Line Resistance Ω 0.403 0.316 0.269 0.155 0.122 0.088 0.092
E2-06
(E4-06)
Motor Leakage Inductance % 20.1 23.5 20.7 18.8 19.9 20 20
E2-10 Motor Iron Loss for Torque Compensation W 508 586 750 925 1125 1260 1600
E3-08 Motor 2 Mid Output Frequency Voltage V 32.2 32.2 32.2 32.2 32.2 27.6 27.6
E3-10 Motor 2 Minimum Output Frequency Voltage V 16.0 16.0 16.0 16.0 16.0 13.8 13.8
E5-02Motor Rated Power HP25304050607575
E5-03 Motor Rated Current A 32.5 38.2 51.8 66.6 74.7 90.8 130.0
E5-05 Motor Stator Resistance Ω 0.276 0.217 0.165 0.107 0.087 0.064 0.022
E5-06 Motor d-Axis Inductance mH 7.95 6.8 5.15 3.62 3.59 2.87 1.80
E5-07 Motor q-Axis Inductance mH 11.94 10.22 8 5.63 5.55 4.44 2.80
E5-09 Motor Induction Voltage Constant 1 mV/(rad/sec) 513.7 522.3 520.8 490.2 552 554.4 1280.0
L8-02 Overheat Alarm Level °C 115 120 120 110 120 130 130
L8-06 Input Phase Loss Detection Level % 26.0 18.0 17.0 18.0 20.0 20.0 29.0
L8-35 Installation Method Selection – 2222222
n5-02 Motor Acceleration Time s 0.317 0.355 0.323 0.32 0.387 0.317 0.533
n9-60 A/D Conversion Start Delay μsec 114.0 14.0 14.0 14.0 14.0 14.0 14.0
No. Name Unit Default Settings
– Model CIMR-LU – 40180 40216 40260 40304 40370 40450 40605
o2-04 Drive Model Selection Hex. A6 A7 A8 A9 AA AC AE
E2-11 Motor Rated Output HP 125 150 200 250 300 350 400
C5-17 Motor Inertia
kgm
2
1.10 1.90 2.10 3.30 3.60 4.10 11.00
C6-03Carrier Frequency kHz2222222
E2-01
(E4-01)
Motor Rated Current A 156 190 223 270 310 370 500
E2-02
(E4-02)
Motor Rated Slip Hz 1.4 1.4 1.38 1.35 1.3 1.3 1.25
E2-03
(E4-03)
Motor No-Load Current A 40 49 58 70 81 96 130
E2-05
(E4-05)
Motor Line-to-Line Resistance Ω 0.056 0.046 0.035 0.029 0.025 0.020 0.014
E2-06
(E4-06)
Motor Leakage Inductance % 20 20 20 20 20 20 20
E2-10 Motor Iron Loss for Torque Compensation W 1760 2150 2350 2850 3200 3700 4700
E3-08 Motor 2 Mid Output Frequency Voltage V 27.6 27.6 27.6 27.6 27.6 27.6 27.6
E3-10 Motor 2 Minimum Output Frequency Voltage V 13.8 13.8 13.8 13.8 13.8 13.8 13.8
E5-02 Motor Rated Power HP 75 75 100 100 100 100 100
E5-03 Motor Rated Current A 130 130 130 130 130 130 130
E5-05 Motor Stator Resistance Ω 0.022 0.022 0.022 0.022 0.022 0.022 0.022
E5-06 Motor d-Axis Inductance mH 1.80 1.80 1.80 1.80 1.80 1.80 1.80
E5-07 Motor q-Axis Inductance mH 2.80 2.80 2.80 2.80 2.80 2.80 2.80
E5-09 Motor Induction Voltage Constant 1 mV/(rad/sec) 1280.0 1280.0 1280.0 1280.0 1280.0 1280.0 1280.0
L8-02 Overheat Alarm Level °C 120 120 125 130 140 140 140
L8-06 Input Phase Loss Detection Level % 17 25 25 20 18 28 23
L8-35 Installation Method Selection – 0 0 0 0 0 0 0
n5-02 Motor Acceleration Time s 0.592 0.646 0.673 0.777 0.864 0.910 1.392
n9-60 A/D Conversion Start Delay μsec 14.0 14.0 14.0 14.0 14.0 14.0 14.0