5.4 d: Reference Settings
184 YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
■ d1-19: Nominal Speed
Sets the nominal speed when a multi-function input terminal is programmed for “Nominal speed” (H1- = 50).
■
d1-20, d1-21, d1-22: Intermediate Speeds 1 to 3
Sets intermediate speeds 1 through 3.
■
d1-23: Releveling Speed
Sets the releveling speed when a multi-function input terminal is programmed for “Releveling speed” (H1- = 52).
■
d1-24: Inspection Operation Speed
Sets the inspection speed when a multi-function input terminal is programmed for “Inspection speed” (H1- = 54). A
description of the inspection speed can be found in Inspection Operation on page 128.
■
d1-25: Rescue Operation Speed
Determines the speed during Rescue Operation. Refer to Rescue Operation on page 134 for details.
■
d1-26: Leveling Speed
Sets the inspection speed when a multi-function input terminal is programmed for “Leveling speed” (H1- = 53).
No. Parameter Name Setting Range Default
d1-19
<1> Setting ranges and defaults vary by the setting units determined by parameter o1-03. Refer to Defaults and Setting Ranges by Display Unit
Selection (o1-03) on page 442 for details.
Nominal Speed 0.00 to 100.00%
<1>
100.00%
<1>
No. Parameter Name Setting Range Default
d1-20
<1> Setting ranges and defaults vary by the setting units determined by parameter o1-03. Refer to Defaults and Setting Ranges by Display Unit
Selection (o1-03) on page 442 for details.
Intermediate Speed 1 0.00 to 100.00%
<1>
0.00%
<1>
d1-21 Intermediate Speed 2 0.00 to 100.00%
<1>
0.00%
<1>
d1-22 Intermediate Speed 3 0.00 to 100.00%
<1>
0.00%
<1>
No. Parameter Name Setting Range Default
d1-23
<1> Setting ranges and defaults vary by the setting units determined by parameter o1-03. Refer to Defaults and Setting Ranges by Display Unit
Selection (o1-03) on page 442 for details.
Releveling Speed 0.00 to 100.00%
<1>
0.00%
<1>
No. Parameter Name Setting Range Default
d1-24
<1> Setting ranges and defaults vary by the setting units determined by parameter o1-03. Refer to Defaults and Setting Ranges by Display Unit
Selection (o1-03) on page 442 for details.
Inspection Operation Speed 0.00 to 100.00%
<1>
50.00%
<1>
No. Parameter Name Setting Range Default
d1-25
<1> Setting ranges and defaults vary by the setting units determined by parameter o1-03. Refer to Defaults and Setting Ranges by Display Unit
Selection (o1-03) on page 442 for details.
Rescue Operation Speed 0.00 to 100.00%
<1>
10.00%
<1>
No. Parameter Name Setting Range Default
d1-26
<1> Setting ranges and defaults vary by the setting units determined by parameter o1-03. Refer to Defaults and Setting Ranges by Display Unit
Selection (o1-03) on page 442 for details.
Leveling Speed 0.00 to 100.00%
<1>
8.00%
<1>