5.11 S: Elevator Parameters
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual 263
Parameter Details
5
S3-26: DC Injection Gain in Motoring Operation
In OLV Control, S3-26 sets a gain level for DC Injection at stop (S1-03) when the motoring load reaches 100%. At that
time, the current applied during DC Injection at stop is determined as S1-03 × S3-26.
S3-27: Torque Compensation Value with Load Condition 1
Adjusts the analog signal from a load sensor for torque compensation. Refer to Adjusting the Torque Compensation at
Start on page 131 for details.
S3-28: Torque Compensation Value with Load Condition 2
Adjusts the analog signal from a load sensor for torque compensation. Refer to Adjusting the Torque Compensation at
Start on page 131 for details.
S3-29: Analog Input from Load Sensor with Load Condition 1
Adjusts the analog signal from a load sensor for torque compensation. Refer to Adjusting the Torque Compensation at
Start on page 131 for details.
S3-30: Analog Input from Load Sensor with Load Condition 2
Adjusts the analog signal from a load sensor for torque compensation. Refer to Adjusting the Torque Compensation at
Start on page 131 for details.
S3-34: Anti-Rollback Torque Bias 1
Sets an intermediary value for the torque bias used for Anti-Rollback when Position Lock at start is performed. This
setting rarely needs to be changed.
S3-35: Anti-Rollback Torque Bias 2
Sets a maximum value for the torque bias used for Anti-Rollback when Position Lock at start is performed. This setting
rarely needs to be changed.
No. Parameter Name Setting Range Default
S3-26 DC Injection Gain in Motoring Operation 0 to 400% 20%
No. Parameter Name Setting Range Default
S3-27 Torque Compensation Value with Load Condition 1 -100.0 to 100.0% -50.0%
No. Parameter Name Setting Range Default
S3-28 Torque Compensation Value with Load Condition 2 -100.0 to 100.0% 50.0%
No. Parameter Name Setting Range Default
S3-29 Analog Input from Load Sensor with Load Condition 1 -100.0 to 100.0% 0.0%
No. Parameter Name Setting Range Default
S3-30 Analog Input from Load Sensor with Load Condition 2 -100.0 to 100.0% 100.0%
No. Parameter Name Setting Range Default
S3-34 Anti-Rollback Torque Bias 1 0.0 to 100.0% 0.0%
No. Parameter Name Setting Range Default
S3-35 Anti-Rollback Torque Bias 2 0.0 to 100.0% 0.0%