EasyManua.ls Logo

YASKAWA L1000A - Page 343

YASKAWA L1000A
522 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.4 Drive Cooling Fans and Circulation Fans
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual 343
Periodic Inspection &
Maintenance
7
4. Turn over the cooling fan unit. Guide the lead wires so that they are held in place by the cable hooks and place
the circulation fan connectors between the fan and fan unit.
Figure 7.37
Figure 7.37 Cooling Fan Wiring: 40450 and 40605
5. Replace the cooling fans
Figure 7.38
Figure 7.38 Fan Unit Disassembly: 40450 and 40605
6. Position the protective tube so that the fan connector sits in the center of the protective tube. (Only for circuit
board cooling fans)
7. Guide lead wires through the hooks provided so that the wires are held in place.
Figure 7.39
Figure 7.39 Cooling Fan Wiring: 40450 and 40605
8. Double check the relay connector to ensure that it is properly connected.
A Circuit Board Cooling Fan C Relay Connector
B Circuit Board Cooling Fan
Case
Circulation Fan B5 Circulation Fan B4
YEA_TMo
nly
A
C
B
YEA_TMonly
Protective tube
YEA_TMon
ly
Circuit board cooling fan Circuit board cooling fan
Relay connector Relay connector
Hook
YEA_TMo
nly
SIEP_C710616_38F_5_0.book 343 ージ 015年11月9日 月曜日 午後3時36分

Table of Contents

Other manuals for YASKAWA L1000A

Related product manuals