8.2 Drive Options and Peripheral Devices
354 YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Interface Options
Remote Operator Cable
WV001/WV003
Extension cable (1 m or 3 m) to connect the digital operator for
remote operation
RJ-45, 8 pin straight through, UTP CAT5e cable
USB Copy Unit JVOP-181
Allows the user to copy and verify parameter settings between
drives. Can also be used as an adapter to connect the drive to
the USB port on a PC.
Attachment
Installation Support Set A EZZ020642A
For installing the digital operator keypad on the outside of an
enclosure panel that houses the drive. Uses screws to secure the
operator.
Installation Support Set B EZZ020642B
For installing the digital operator keypad on the outside of an
enclosure panel that houses the drive.
Uses nuts to secure the operator for installations where screws
are not practical.
Others
24 V Power Supply
200 V class: PS-A10LB
400 V class: PS-A10HB
600 V class: PS-A10HB
Provides power to the control circuit and option boards in the
event of power loss. Allows the user to monitor drive settings
and fault information when the main circuit has no power.
– DriveWizard Plus – PC tool for drive setup and parameter management
Communication Options
Complementary Signal Encoder PG-B3
For speed feedback input by connecting a motor encoder
Input: 3 track (can be used with one or two tracks), for HTL
encoder connection, 50 kHz max
Output: 3 track, open collector
Encoder power supply: 12 V, max current 200 mA
Line Driver Encoder PG-X3
For speed feedback input by connecting a motor encoder
Input: 3 track (can be used with one or two tracks), line driver,
300 kHz max
Output: 3 track, line driver
Encoder power supply: 5 V or 12 V, max current 200 mA
EnDat or HIPERFACE Encoder
PG-F3
Encoder type: EnDat 2.1/01, EnDat 2.2/01, EnDat 2.2/22
(HEIDENHAIN) and HIPERPACE (SICK STEGMANN)
Maximum input frequency: 20 kHz
Pulse monitor: Matches RS-422 level
Output voltage: 5 V±5%, 8 V±10%
Maximum output current: 200 mA
Wiring length: 20 m max. for the encoder, 30 m max. for the
pulse monitor
ERN1387 Encoder
PG-E3
Encoder type: ERN1387 (HEIDENHAIN)
Maximum input frequency: 20 kHz
Pulse monitor: Matches RS-422 level
Output voltage: 5 V±5%
Maximum output current: 200 mA
Wiring length: 20 m max. for the encoder, 10 m max. for the
pulse monitor
Analog Monitor
AO-A3
Provides extra analog output terminals for monitoring drive
status.
Output channels: 2
Output voltage: -10 to 10 V, 11 bit (signed)
Digital Input
DI-A3
Used to set the speed reference by digital inputs
Input channels: 18 (including SET signal and SIGN signal)
Input signal type: BCD 16 bit (4 digit), 12 bit (3 digit), 8 bit (2
digit)
Input signal: 24 Vdc, 8 mA
Digital Output
DO-A3
Provides extra insulated digital outputs for monitoring drive
status.
Photocoupler relays: 6 (48 V, up to 50 mA)
Contact relays: 2 (250 Vac/up to 1 A, 30 Vdc/up to 1 A)
CANopen SI-S3 Connects to a CANopen network
Option Model Number Description
Copy
Verify
Read
LOCK
YASKAWA
JVOP-181
USB Copy Unit
COM ERR
SIEP_C710616_38F_5_0.book 354 ページ 2015年11月9日 月曜日 午後3時36分