1-24
z Click the Global Setup tab.
z Select Enable from the LLDP Enable dropdown list.
z Click Apply.
Configuration verification
# Display the status information of port GigabitEthernet1/0/2 on Switch A.
z Select Network > LLDP from the navigation tree to enter the Port Setup tab.
z Click the GigabitEthernet1/0/2 port name in the port list.
z Click the Status Information tab at the lower half of the page. The output shows that port
GigabitEthernet 1/0/2 is connected to a non-MED neighbor device, that is, Switch B, as shown in
Figure 1-20.
Figure 1-20 The Status Information tab
# Tear down the link between Switch A and Switch B.
# Display the status information of port GigabitEthernet1/0/2 on Switch A.
z Click Refresh. The updated status information of port GigabitEthernet 1/0/2 shows that no
neighbor device is connected to the port, as shown in
Figure 1-21.
Figure 1-21 The Status Information tab displaying the updated port status information