Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
1500.00 rpm / real32Defines the trigger level for “above limit” indication in speed
control. When actual speed exceeds the limit, bit 10 of 6.17
Drive status word 2 is set.
Above speed limit46.31
- / -“Above limit” indication trigger level for speed control. For
scaling, see parameter 46.1.
0.00 ... 30000.00 rpm
50.00 Hz / real32Defines the trigger level for “above limit” indication in
frequency control. When actual frequency exceeds the
limit, bit 10 of 6.17 Drive status word 2 is set.
Above frequency limit46.32
- / -“Above limit” indication trigger level for frequency control.
For scaling, see parameter 46.2.
0.00 ... 1000.00 Hz
300.0 % / real32Defines the trigger level for “above limit” indication in torque
control. When actual torque exceeds the limit, bit 10 of
6.17 Drive status word 2 is set.
Above torque limit46.33
- / -“Above limit” indication trigger level for torque control. For
scaling, see parameter 46.3.
0.0 ... 1600.0 %
1 / uint16Defines the number of decimal places of torque-related
parameters.
Torque decimals46.42
1 = 1 / 1 = 1Number of decimal places of torque parameters.0...2