Function blocks
249
1SVC 440 795 M1100
Time range
Inputs
The function block inputs
>I1 and >I2 can have the
following operands:
•Constants
Markers MD, MW, MB
Analog inputs IA01 to IA04
IA01: Terminal I7
IA02: Terminal I8
IA03: Terminal I11
IA04: Terminal I12
Analog output QA01
Actual value …QV> of another function block
Outputs
Actual value …QV>
The actual value …QV> can be assigned the following
operands:
Markers MD, MW, MB
Analog output QA01
Parameter Time range and setpoint time Resolution
S 000.000 Seconds, 0.005 to 999.995 s for constants
and variable values
5ms
M:S 00:00 Minutes: Seconds 00:00 to 99:59 only for
constants and variable values
1s
H:M 00:00 Hours: Minutes, 00:00 to 99:59 only for
constants and variable values
1 min.
h
Minimum time setting:
0.005 s (5 ms).
If a time value is less than the display system cycle time,
the elapsed time will only be recognised in the next cycle.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB CL Series and is the answer not in the manual?

ABB CL Series Specifications

General IconGeneral
ManufacturerABB
Rated Control Supply Voltage (Us)24 V DC
MountingDIN Rail
CategoryRelays
Contact ConfigurationSPDT
Coil Voltage24 V DC
Operating Temperature-40°C to +70°C
Electrical Life100 Thousand Cycles
OutputRelay

Related product manuals