Output Type Description
Entry Status This output activates if an ‘All Okay’ entry procedure is implemented and there is no alarm
generated, that is, the ‘All Okay’ button is pressed within the configured time after the user
code is entered.
Warning Status This output activates if an ‘All Okay’ entry procedure is implemented and a silent alarm
generated, that is, the ‘All Okay’ button is not pressed within the configured time after the user
code is entered.
Ready to Set This output activates when an area is ready to set.
Setting ACK This output signals the setting status. The output toggles for 3 seconds to signal that the
setting has failed. The output remains on for 3 seconds if setting is successful.
Fullset Done This output activates for 3 seconds to signal that the system has been fullest.
Blockschloss 1 Used for normal Blockschloss devices.
When all zones in an area are closed, and there are no pending faults, the ‘Blockschloss 1‘
output is activated. If the lock on the Blockschloss is closed, a ‘Keyarm‘input is activated, the
relevant area is set and the ‘Setting Ack‘output is activated for 3 seconds to signal that the
setting was successful. ‘Blockschloss 1‘is not deactivated.
If the Blockschloss is unlocked, the Blockschloss device deactivates the Keyarm input to the
unset state (closed) and the area is unset. ‘Blockschloss 1‘is then deactivated.
Blockschloss 2 Used for Blockschloss device type - Bosch Blockschloss, Sigmalock Plus, E4.03.
When all zones in an area are closed, and there are no pending faults, the ‘Blockschloss 2‘
output is activated. If the lock on the Blockschloss is closed, a ‘Keyarm‘input is activated, the
relevant area is set and the ‘Setting Ack‘output is activated for 3 seconds to signal that the
setting was successful. ‘Blockschloss 2‘is then deactivated.
If the Blockschloss is unlocked, the Keyarm zone is switched to unset (closed) and the area is
unset. ‘Blockschloss 2‘is activated (if area is ready to set).
Lock Element Activates if the Lock Element is in the ‘locked‘position.
Unlock Element Activates if the Lock Element is in the ‘unlocked‘position.
Code Tamper Activates if there is a code tamper in the area. Clears when state is reset.
Trouble Activates if any zone is in trouble state.
Ethernet Link Activates if there is a fault on the Ethernet link.
Network Fault Activates if there is an EDP communications fault.
Glass Reset Used to switch on the power for the glassbreak interface module and to remove power in
order to reset the device. The output is reset if a user enters their code, the zone is not in the
closed state, and the bells deactivated.
Confirmed
holdup
Activates in the following scenarios for PD6662 compliance:
l
two hold-up zone activations more than two minutes apart
l
a hold-up zone and a panic zone activation more than two minutes apart
l
if a hold-up zone and a tamper zone or a panic zone and a tamper zone activation occurs
within the two minute period
Full Engineer Activates if an engineer is on site and the system is in full engineer mode.
SPC42/52/53/63 Installation & Configuration Manual Engineer programming via the keypad
© Vanderbilt 2023 107 I-200572