15.6.2.1 Expander Status
1. Select Status > Hardware > X-Bus Status.
2. Select the Expanders tab.
A list of detected expanders and any associated PSUs displays.
The following table shows the information that is available.
Expander ID This ID number is a unique identifier for the expander.
Description Text description of the expander. This text will also appear on the browser and keypad.
Type The type of expander detected (I/O, PSU, keypad, etc.).
S/N The serial number of the expander.
Version The firmware version of the expander.
Comms The status of the expander (online or offline).
Status The status of the expander (OK, Fault, OP Tamper).
PSU The type of PSU that is fitted to the expander, if applicable. Click the PSU to view the PSU
status.
Performable actions
Refresh Click the button to update the status of the X-BUS.
To view more status information:
l
Click any of the expander’s identifying parameters (ID, description, type, serial number) to
display further status details.
The following table shows the information that is available.
Name Description
Communication The physical status (OK, Fault) and the programmed status (OK, Isolated, Inhibited) of
the X-BUS cable connection to the expander.
Housing Tamper The physical and programmed status of the expander housing tamper.
Fuse Fault The physical and programmed status of the expander fuse.
Controller Mains
Fault
The physical and programmed status of the mains supply to the controller.
Battery Fault The physical and programmed status of the battery.
PSU Fault The physical and programmed status of the PSU.
OP Tamper The physical and programmed status of the tamper outputs on the PSU.
Low Voltage Indication of battery low voltage status.
Performable actions
Name Description
Restore
Alerts
Click the button to restore all alerts on the panel.
SPC42/52/53/63 – Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2023 128 I-200572