Input zones: attributes
Each zone on the SPC can be assigned an attribute that determines the properties of that zone.
To assign an attribute to a zone:
1. Select Configuration > Hardware > Controller > Attributes.
Check the box beside the preferred attribute.
The attributes presented on this page will depend on the type of zone selected. For a list of
assignable attributes, see Applicable attributes to zone types on page1.
15.10.1.2 Editing an output
1. Select Configuration > Hardware > Controller.
2. Configure the fields as described in the table below.
Output Type
l
System Output: Select the type from the dropdown menu. (See Outputs
types and output ports below.)
l
Area Output: Only if (multiple) Areas is activated in menu Panel
Settings > System Settings > Options. Select an area and the type of
system output for this area. (See Outputs types and output ports below.)
l
Zone Mapping: Select which zone should be mapped.
l
Mapping Gate: Select which mapping gate should be mapped.
l
Door Output: Select the door number and the type of system output for
the door. (See Outputs types and output ports below.)
l
Keyswitch: Select the node ID for the required keyswitch and the
required key position to map to this output.
Description Enter a text describing the output (max. 16 characters). This text will also
appear on the browser and keypad.
Output
Attributes
l
Mode: Select the operational mode. Continuous follows output type;
Pulsed toggles on and off when output type is active; Momentary
generates a pulse when output type activates.
l
Retrigger: Tick the box to retrigger momentary outputs.
l
On Time: Enter the On time that applies to momentary and pulsed
outputs.
l
Off Time: Enter the Off time that applies to pulsed outputs.
l
Invert: Tick this box to invert the physical output.
l
Log: Tick this box to log the output state changes to the event log.
l
Calendar: Select if necessary the desired calendar. See Calendars on
page197.
See also
Calendars on page197
Outputs types and output ports
Each output type can be assigned to one of the 6 physical output ports on the SPC controller or to an
output on one of the connected expanders. Output types that are not assigned to physical outputs act as
indicators of events on the system and may be logged and/or reported to remote central stations if
required.