The X-Bus cable Map – Warning(s) page displays.
3. Click Proceed Reconfiguration.
The X-BUS is reconfigured.
If an expander is offline and the reconfigure button is pressed, the expander will disappear
without notifying the user.
See also
l
Wiring the system on page35
l
Zone attributes on page283
l
Zone types on page278
Configuring an Indicator Expander
The LED indicator module has 1 input.
There are 2 possible configuration modes for the indication expander:
l
Linked Mode
l
Flexible Mode
1. Select Configuration > Hardware > X-Bus > Expanders.
2. Click one of the indicator identifying parameters.
The Linked Mode configuration page displays.
Linked Mode
1. Enter a description.
2. Select if indicator module should be limited to a valid code entered on a keypad.
3. Select the areas that are to be controlled by the 4 functions keys.
4. Select if LED indicators should be active when the keys are deactivated.
5. Configure the input.
Flexible Mode
1. Click the Flexible Mode button.
2. Configure the fields described in the table below.
Function Keys
Area Select the area is to be controlled by the function key.
Function Select the function to be performed by this key in this area.
Location Select an area if the indicator module is located in a secure area.
Visual Indication
Indicator There are 8 indicators/LEDs on the right and 8 indicators/LEDs on the left
side.
Function The function that is indicated by this LED.
Function On Select the colour and the state for every indicator if the selected function is
ON.
SPC42/52/53/63 – Installation & Configuration Manual Engineer programming via the browser