Restriction System Option Description
Partset
Partset A
Rename
Enter a new name for your PARTSET A mode (for example, Night Mode).
Partset B
Rename
Enter a new name for your PARTSET B mode (for example, Floor 1 only).
Alarm
Bell on First Enable to activate relevant bells/sirens on an unconfirmed alarm. When this
option is disabled, the relevant bells/sirens will only activate on a confirmed
alarm or if the detector that caused the unconfirmed alarm is reactivated.
Bell Retrigger Enable to resound bells/sirens if a second zone activation is detected (after
the bell time has elapsed). If not checked then the external bells will only
trigger once.
Web Only
Alert Forbid Set If enabled, a user cannot set an area if there is an area or system alert
present on the system.
Note: This option is only available when the Standards > Region selected
is Switzerland or Security Grade selected is ‘Unrestricted’.
Restore on Unset Enable for alerts to auto clear after 30 seconds in Unset mode.
Note: To comply with PD6662, you must disable this option.
Antimask Set Select the type of event reported resulting from antimask detection when
panel is Set. Options are Disabled, Tamper, Trouble or Alarm.
The option can only be configured when the panel is in ‘Unrestricted’ mode.
In Grade 2 or 3 mode, the type of event reported is in accordance with the
standards for the selected region:
l
Ireland - Alarm
l
All other regions - Alarm
Antimask Unset Select the type of event reported resulting from antimask detection when
panel is Unset. Options are Disabled, Tamper, Trouble or Alarm.
The option can only be configured when the panel is in ‘Unrestricted’ mode.
In Grade 2 or 3 mode, the type of event reported is in accordance with the
standards for the selected region:
l
Ireland - Disabled
l
All other regions - Tamper
Out of bounds
EOL unset
Select the type of event reported resulting from Out of Bounds EOL
detection when the panel is unset. Options are: Disabled, Tamper and
Trouble.
The option can only be configured when the panel is in ‘Unrestricted’ mode.
In Grade 2 or 3 mode, the type of event reported is in accordance with the
standards for the selected region:
l
Germany VDS – Tamper
l
All other regions - Trouble
SPC42/52/53/63 – Installation & Configuration Manual Engineer programming via the browser