the key to the left sets the delay to three minutes (non-configurable). This can be done regardless
of how many times setting was delayed.
3. Using a FOB, WPA or button which activates a Delay Autoset trigger action.
Temporary Unset
To allow a system to be temporarily unset in a time period specified by a calendar, the following three
parameters need to be configured:
1. Calendar
A calendar needs to be configured and selected for this area.
2. Time Locked
This box needs to be ticked so that the area can be unset only when allowed as per the configured
calendar.
3. Unset Duration
This parameter needs to be set to a value greater than zero to set an upper limit on the time the
area will be unset.
All Okay
All Okay
Required
If selected, user must confirm ‘All okay’ input or silent alarm is generated. See Editing a zone on
page185 for details on configuring an ‘All Okay’ zone input.
All Okay
Time
Time (in seconds) in which ‘All okay’ must be confirmed before alarm is raised. (Range: 1–999
seconds)
All Okay
Event
Select the event type to be sent when the ‘All okay’ timer expires. Options are Panic (Silent), Panic
and Duress.
RF Output
RF Output Time Enter the number of seconds that the RF Output will remain on for.
0 seconds will toggle the output on and off.
Fire Exit Route
Fire exit
route
Select the doors which will open when fire occurs in this area. This option does not display in
domestic mode.
Area Triggers
The Triggers section is only displayed if triggers have been defined previously. (See Triggers on
page201.)
Click the Edit button to add, edit or delete trigger conditions for the area.
Configure the trigger for the area using the following parameters:
Trigger Select a trigger from the drop down list.
Edge The trigger can activate from either the positive or negative edge of the activation signal.
SPC42/52/53/63 Installation & Configuration Manual Engineer programming via the browser