Auto Set
Warning
Enter the number of minutes to display a warning before Auto Setting. (0–30)
Note that the panel sets either at the scheduled time or at the time defined by the Delay Unset
parameter. The first warning is displayed at the configured time before the scheduled time.
There are further warnings starting at one minute before setting time.
Auto Set
Cancel
Enables the user to cancel Auto Setting by entering a code in the keypad.
Auto Set
Delay
Enables a user to delay Auto Setting by entering a code in the keypad.
Keyswitch Enables Auto Setting to be delayed using Keyswitch Expander.
Delay
Interval
Enter the number of minutes by which to delay Auto Set. (1–300 )
Delay
Counter
Enter the number of times that Auto Setting can be delayed. (0–99: 0=unlimited)
Delay Unset Enter the number of minutes by which to delay an Unset. (0=nodelay)
Interlock
Group
Select an Interlock Group to assign to this area. Interlocking only allows one area within the
group to be Unset at any time. Typically used in ATM areas.
Unset
Duration
If area is Unset for longer than this it will Set automatically. (Range 0–120 mins: 0=notactive).
Dual PIN If this option is enabled, two PINs are required to Set or Unset the area with the keypad. Both
PINs must belong to users who have the required user right for the operation (Setting or
Unsetting).
If the second PIN is not entered within 30 seconds, or it is wrong, then the area cannot be Set
or Unset.
Force Set
Mode
Area options for Force-set operation (Normal or Blocked).
Auto
Restore on
Force Set
Check this option to auto-restore closed zones during force-set. If this option is selected, if an
alert is active or a zone needs to be restored, then it will be automatically restored.
Late Working Support
An example of using the setting and unsetting parameters is for late working situations where a
calendar has been configured for automatic setting of a premises at a particular time but staff may
need to work late on occasion and the automatic setting needs to be delayed.
Each delay is determined by the amount configured in the Delay Interval parameter, and the Delay
Counter parameter determines the number of times that setting can be delayed. A user needs the
correct value in the Auto Set Delay in order to use this feature.
There are three ways to delay setting:
1. Entering the PIN on the keypad.
DELAY is a menu option on the standard keypad. The buttons at the top of the comfort keypad
are used to operate the delay feature
2. Using the keyswitch.
Turning the key to the right delays setting the system by the configured delay if the maximum
number of times that setting can be delayed (Delay Counter) has not been exceeded. Turning
SPC42/52/53/63 Installation & Configuration Manual Engineer programming via the browser