Time
Locked
Select this option to time lock the area as per the selected Calendar. (Vault type area in
Financial mode only)
Vault
Access
Enter the number of minutes (0–120) to activate this timer at the end of a Time Locked Unset
period. If the area is not unset after this timer expires, the area cannot be unset until the start of
the next Time Locked Unset period. (Vault type area in Financial mode only)
Reporting
The Reporting configuration settings are applicable for Standard Areas in Commercial and
Financial installations only and are only relevant if a calendar has been selected. (See Schedule on
the previous page.)
These settings enable a report to be sent to the Control Centre or nominated personnel if the panel is
Set or Unset outside scheduled calendar times.
Early to
Set
Enables a report to be sent if the panel is manually Fullset before a scheduled Set and before the
number of minutes entered in the Timer field.
Late to
Set
Enables a report to be sent if the panel is manually Fullset after a scheduled Set and after the
number of minutes entered in the Timer field.
Early to
Unset
Enables a report to be sent if the panel is manually Unset before a scheduled Unset and before the
number of minutes entered in the Timer field.
Late to
Unset
Enables a report to be sent if the panel is manually Unset before a scheduled Unset and before the
number of minutes entered in the Timer field.
Reporting is done via SMS or to the ARC via SIA and Contact ID. An event is also stored in the system
log.
Only events configured for late or early reporting for the area will be reported.
Event reporting must also be enabled for an ARC or SMS, as described in the following sections.
Enabling Reporting of Unusual Setting/Unsetting for an ARC
To configure event reporting for an ARC configured to communicate over SIA or CID, select
Communications > Reporting > Analog ARC > Edit >Filter to display the Event Filter page for an
ARC.
The Early/Late parameter is enabled to report any setting or unsetting which differs from the schedule.
Enable Reporting of Unusual Setting/Unsetting for SMS
SMS Events can be configured using both Engineer and User configuration pages.
For Engineer configuration, select Users > Users SMS > Engineer SMS > Edit.
Enable Early/Late to report any setting and unsetting which is not according to schedule.
Setting/Unsetting
The following parameters (with the exception of the Interlock parameter) are only relevant in the
following cases:
l
A Calendar is selected (see Schedule on the previous page), or
l
Unset Duration is enabled (has a value greater than zero), or
l
Both of the above conditions are met.
SPC42/52/53/63 Installation & Configuration Manual Engineer programming via the browser