Partset
Timed
Tick the relevant checkbox (Partset A or B) to apply the exit timer to the Partset A or B mode.
Partset
Access
Tick the relevant checkbox to change access zones into entry/exit type zones for either Partset A
or B operation. This feature is useful for a domestic installation where a Passive Infrared (PIR)
sensor is located in the hallway. If the user partsets the system at night and returns downstairs
during the night, he/she may unintentionally activate the PIR sensor in the hallway and trigger the
alarm. By setting the partset access option, the buzzer will sound for the entry time period when
the PIR sensor is activated thereby warning the user that the alarm will activate if no action is
taken.
Partset
Exit/Entry
Tick the relevant checkbox to change the behaviour of entry/exit zones to alarm zones when in
Partset A or B mode. This feature is useful for a domestic installation when the system has been
set in partset mode. If the user partsets the system at night he/she may wish the alarm to activate
immediately if the front or back door is opened during the night.
Partset
Local
Tick the relevant checkbox to restrict the reporting of alarms in Partset Mode to local reporting only
(No remote reporting).
No Bells If ticked, no bells will be activated for partset A or B.
Linked Areas
This section enables you to link areas for setting and unsetting purposes:
Fullset Fullset this area when all linked areas are Fullset.
Fullset All Fullset all areas when this area is Fullset.
Prevent Fullset Prevent this area from Fullset if all linked areas are Fullset.
Prevent Fullset All Prevent linked areas from Fullset if this area is not Fullset.
Unset Unset this area when all linked areas are Unset.
Unset All Unset all areas when this area is Unset.
Prevent Unset Prevent this area from Unset if any linked areas are Fullset.
Prevent Unset All Prevent linked areas from Unset if this area is Fullset.
Authorise Setting Enable authorised setting for linked areas. Refer Authorised Setting of the Blocking
Lock.
Linked Areas Click the areas that you wish to link to this area.
Schedule
Configure scheduling with the following settings:
Calendar Select a calendar to control scheduling.
Unset Select if area should automatically Unset as per the time specified in the selected calendar.
Fullset Select this option to Fullset the area as per the time specified in the selected Calendar. The
area will also set when the Unset Duration or Delay Interval has elapsed (see Setting/Unsetting
on the next page). If the Unset Duration overlaps the scheduled time, the area will use the
calendar settings.