Entry/Exit
Configure the following Entry/Exit settings:
Entry time The time period (in seconds) allowed for the user to UNSET the alarm after opening an
entry/exit zone of an armed system. The entry time applies to all entry/exit zones in that area
(default: 45 seconds).
Entry Time 2
Exit time The time (in seconds) allowed for a user to leave a protected area before setting is complete.
The exit time will be counted down at the keypad as the buzzer beeps to indicate to the user
that the system will arm when the exit timer reaches zero. The exit time applies to all entry/exit
zones in that area (default: 45 seconds).
Disable Exit
Time
Select if no exit timer is required and setting is activated by ‘Exit term’ zone or ‘Entry exit’ zone
with ‘Final exit’ attribute. See Timers on page179.
Fob Unset
Entry
FOB will only unset when entry timer is running. Default is enabled.
Access Denied
on Alarm
Access is temporarily denied to the area for the amount of time specified in the Lockout Post
Alarm timer.
Prevent Setting If enabled, setting prevented from keypad
Prevent
Unsetting
If enabled, unsetting prevented from the keypad.
Setting
Authorisation
Used for configuring Blocking Lock operation. Options are:
l
Disabled
l
Set
l
Unset
l
Set and Unset
If the Disabled option is selected (default) then the system will set and unset normally with no
change of operation.
If the Set option is selected, a “Setting Authorisation” signal is required to set this area which
can be received from keypads or a zone input (see Authorised Setting of the Blocking Lock)
The user cannot set the system from the keypad. Any area that requires setting authorisation
will appear as locked on the comfort keypad and will not appear on the standard keypad when
setting.
If the Unset option is selected, the user cannot unset the area from keypads but can use the
keypad to generate the setting authorization signal.
For the set and unset options, the user will be unable to change the state of the area at any
stage from the keypad.
A timer for setting authorisation can be configured. See Timers on page179.
Partset Options
Configure the operation of particular zones for both Partset A and Partset B modes as detailed below:
Partset
Enable
Enable PartSet for A and B operation as required.
SPC42/52/53/63 Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2023 187 I-200572