The SMS test is provided only for the purpose of ensuring the SMS feature is operating correctly. A
short text message using alphabetic characters (A-Z) should be used to test this feature.
PSTN modem
1. Select Communications > Communications > Modems.
2. Click Configure.
3. Configure the fields as described in the table below.
PSTN Modem settings
Country Select the country that the SPC is installed in.
Incoming
Calls
The modem can be programmed to answer calls based on the following conditions:
l
Don’t answer incoming calls Modem never answers calls.
l
Answer after ‘x’ rings Select the number of rings (1 to 8) after which the modem answers
the incoming call.
l
Answer when after one ring phone is hung up, then immediately dialled again If the
calling party calls the modem, hangs up after 1 ring burst only, and then immediately re-calls
the modem. The SPC system knows to automatically answer the call in this condition.
l
Only answer when engineer access is granted The modem only answers the call while
engineer access is granted to the system.
Prefix Enter the number required to access a line (for example, if connected to a PBX).
Line
Monitoring
Enable this feature to monitor the voltage of the line connected to the modem.
Note: EN 50131-9 Confirmation configuration In order for EN50131-9 Confirmation to operate
correctly, line monitoring must be enabled. (See Options on page169.)
Monitoring
Timer
Select the period (in seconds) for which the line voltage must be seen as being incorrect before
the line is deemed by the SPC to be faulty.
Modem Fault
Time
Time delay for a system alert (0–9999 seconds). Default 60 seconds.
SMS Enable Tick this checkbox to enable the SMS feature on the system.
Note: The SMS operates using a standard protocol that is used in SMS telephones. Note that
some PSTN operators do not provide the service of SMS over PSTN. For SMS to operate over
PSTN the following criteria is required:
Caller ID needs to be enabled on the telephone line.
Direct telephone line not through PABX or other comms equipment.
Also note that most Service Providers only allow SMS to a telephone registered in the same
country (this is due to billing issues).
Note: SMS over PSTN is no longer supported. The functionality remains in the product for
backward compatibility.
SMS Server
Number
Only for PSTN. This number automatically displays the default number for SMS for the country
selected. Enter an appropriate phone number of the SMS service provider that is accessible in
your location.
SPC42/52/53/63 Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2023 213 I-200572
08.12.2023