Line
Monitoring
l
Disabled
l
Enable
l
Fullset
Enable this feature to monitor the signal level from the GSM mast connected to the modem.
The Fullset option only enables this feature while the system is Fullset.
Note: EN 50131-9 Confirmation configuration — In order for EN50131-9 Confirmation to
operate correctly, line monitoring must be enabled. (See Options on page169.)
Monitoring
Timer
Enter the time period in seconds for which the signal level must drop to Low before the SPC
system registers a fault. 0 to 9999 seconds range.
Modem Fault
Time
Enter the time delay in seconds before the SPCsystem sends an alert. 0 to 9999 seconds
range.
SMS Enable Tick this checkbox to enable the transmission and reception of SMSmessages and command
control.
Automated
SMS
l
Disabled
l
1 hour
l
24 Hours
l
48 Hours
l
7 Days
l
30 Days
Select the timing for automated SMS messages.
Automated
SMS Number
Enter SMS number to receive automated SMS messages. Only one device can receive these
messages.
Start
Date/Time
Enter the start date and time from when the system will send automated SMS messages.
Mobile Data Configuration
Access Point
(APN)
Enter Access Point details to enable any IP communications. These details are service provider-
dependent.
Access Point
User Name
Enter Access Point details to enable any IP communications. These details are service provider-
dependent.
Access Point
Password
Enter Access Point details to enable any IP communications. These details are service provider-
dependent.
Dial Up Internet Configuration
Dial Up
Internet
Enable
Select this option to enable the modem to gain internet access through a dial-up connection
Phone
Number
Enter the phone number for the dial-up connection.
Username Enter the dial-up connection Username.
Password Enter the dial-up connection Password.
Click the Test SMS button to send a short text message for the purposes of testing the system.
SPC42/52/53/63 – Installation & Configuration Manual Engineer programming via the browser