EasyManua.ls Logo

Acre SPC42 - Page 232

Acre SPC42
297 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GPS Coordinates The GPS coordinates of the installation.
ATS Installer Name The name of the installer of the ATS.
Installer Phone Number 1 The phone number of the installer of the ATS.
Installer Phone Number 2 The phone number of the installer of the ATS.
Notes Any additional information for the RCT.
3. Click Save.
15.11.2.4 Configuring an SPC Connect ATS
The Add SPC Connect ATS functionality opens a communication between the panel (SPT) and the
SPC Connect server (RCT), www.spcconnect.com. Using the generated SPC Connect ATS
Registration ID, a panel user can register a user account and panel with the SPC Connect website to
access their panel remotely.
1. To configure an SPC Connect ATS, go to Communications > FlexC > FlexC ATS.
2. On the ATS Configuration page, click Add SPC Connect to open a communication path with
the SPC Connect server.
An SPC Connect ATS is added to the Event Sequence Table with the following attributes:
l
SPC Connect ATS Registration ID
l
Default ATP over Ethernet. For information on ATP fields, see Add ATP to FlexC RCT on
page220.
l
Default Events Profile for SPC Connect
l
Default Commands Profile for SPC Connect
l
Default RCT URL is www.spcconnect.com
l
The SPT Account Code for the ATP is populated.
l
Make a note of the SPC Connect ATS Registration ID and provide this to the customer
along with the SPCConnect System User Guide.
15.11.2.5 Exporting and Importing an ATS
ATS files have a .cxml extension. You must create the ATS in the SPC browser and export it before
you can import it to a system.
1. To export an ATS, go to Communications > FlexC > FlexC ATS.
2. In the Configured ATS table, locate the ATS to export and click the Export ATS button (green
arrow.
3. Save the file with the default filename export_flexc.cxml or rename the file.
4. To view the file, open in Notepad.
5. To import an ATS into the system, go to Communications > FlexC > FlexC ATS.
6. Scroll down to Import ATS.
7. Click the Browse button and select an ATS to import (.cxml file extension).
8. Click Import ATS.
The ATS displays in the Configured ATS table with the next available ID.
When you export an ATS, the SPT Account Code changes to 0. This prevents an ATS being
exported and then imported and replicating an existing ATS.
SPC42/52/53/63 Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2023 232 I-200572
08.12.2023