Event Protocol
Protocol Protocol used in communication.
l
SIA
l
SIA Extended 1
l
SIA Extended 2
l
Contact ID
Event Profile Select the Event Profile which defines how and which events are
transmitted on this ATS.
l
Use ATS Setting
l
Default Event Profile
l
Default Portal Event Profile
l
All events
l
Custom Event Profile
ATP Faults
ATP
Monitoring
Fault
Select to generate an ATP fault if the ATP monitoring fails or an event
fails to transmit on the ATP.
Event Timeout The amount of time that the ATP will keep trying to transmit the event
until the event fails on the ATP and is passed to the next ATP. Default: 2
minutes.
l
30 seconds
l
60 seconds
l
90 seconds
l
2 minutes
l
3 minutes
l
5 minutes
l
10 minutes
3. Click Save.
Edit Installation Details
The installation details are passed to the RCT to help the operator to identify the panel.
1. Click the Edit Installation Details button.
2. Complete the fields in the table below.
ATS Installation ID The ID of the ATS Installation (1–999999999).
Company ID For future use.
Company Name Name of the company.
ATS Installation Address The address of the ATS installation.
SPC42/52/53/63 – Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2023 231 I-200572