Panel Identification
ATP Sequence
No.
This field displays the sequence number of the ATP in the ATS
configuration. Number 1 is primary, numbers 2–10 are backup
ATP Unique ID This ID uniquely identifies the ATP to the RCT
ATP Name Enter a name for the ATP
SPT Account
Code
Enter a number to uniquely identify the panel to the RCT (1–999999)
ARC Connection
Number 1 Phone number 1
Number 2 Phone number 2
Modem Select Select the modem to be used.
l
Modem 1
l
Modem 2
Test Calls
Test Call Mode
(Non-active
ATP)
Select the mode for sending test calls when the ATP is in non-active
mode. Default: 24 hours.
l
Test calls disabled
l
Test call every 10 minutes
l
Test call every 1 hour
l
Test call every 24 hours
l
Test call every 48 hours
l
Test call every 7 days
l
Test call every 30 days
Test Call Mode
(Active ATP)
Select the mode for sending test calls when the ATP is an active ATP.
Default: 24 hours.
l
Test calls disabled
l
Test call every 10 minutes
l
Test call every 1 hour
l
Test call every 24 hours
l
Test call every 48 hours
l
Test call every 7 days
l
Test call every 30 days
Time of first
test call
Time of first test call after reset or ATS initialization.
l
Send Immediately (default)
or
l
Select a half hour interval between 00:00 and 23:30
SPC42/52/53/63 – Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2023 230 I-200572
08.12.2023