Versatile Service Module
7750 SR OS Services Guide Page 1247
Configure VSM CCAG Components
Use the CLI syntax displayed below to configure the following entities:
Provision VSM on an MDA on page 1247
Cross Connecting Network IP Interfaces on page 1250
Provision CCAG Parameters on page 1248
Configure Path Components on page 1249
Cross Connecting Services on page 1252
Provision VSM on an MDA
Before a CCA module may be utilized in the system, the CCA must be provisioned into an MDA
slot. The MDA provisioning command must be modified to support provisioning a CCA adaptor
type. Up to 8 member CCAs can be configured per CCAG.
CLI Syntax: config>card# mda mda-number mda-type {other-MDA-type|cca}
The following example displays the command usage to provision CCA on an MDA:
Example:config# card 10
config>card# mda 1
config>card>mda# mda-type vsm-cca
config>card>mda# exit
config>card#
The following example displays the configuration:
A:ALA-48>config>card# info
----------------------------------------------
card-type iom-20g
mda 1
mda-type vsm-cca
exit
mda 2
mda-type m20-1gb-tx
exit
----------------------------------------------
A:ALA-48>config>card#