Loading...
Configuring a VPLS Service with CLI
Page 414 7750 SR OS Services Guide
Figure 2: Example Configuration for Protected VPLS SAP
Use the following CLI syntax to create a management VPLS:
CLI Syntax: config>service# sdp sdp-id mpls create
far-end ip-address
lsp lsp-name
no shutdown
CLI Syntax: vpls service-id customer customer-id [m-vpls] create
description description-string
sap sap-id create
managed-vlan-list
range vlan-range
mesh-sdp sdp-id:vc-id create
stp
no shutdown
Example
: config>service# sdp 300 mpls create
config>service>sdp# far-end 10.0.0.20
config>service>sdp# lsp "toALA-A2"
config>service>sdp# no shutdown
config>service>sdp# exit
config>service>vpls# mesh-sdp 300:1 create
config>service>vpls>mesh-sdp# exit
config>service>vpls# no shutdown
ESSMTU
STP
ALA-1
ALA-2
M
M
M
M
M
M
1/1
1/21
2
1/3
1/3
1/1:1
1/1:1
300:1
300:1
SDP 300
1/1:100
1/1:100
1/3
SAP
SAP
SAP
SAP
SAP
MTU runs STP
in VLAN 1
= vpls 1 (m-vpls)
= vpls 10 (user vpls)
OSSG047