Page 280 7750 SR OS Services Guide
The following displays an example of the T-PE2 configuration.
T-PE2
*A:ALA-T-PE2>config>service>epipe# info
----------------------------------------------
endpoint "x" create
exit
endpoint "y" create
exit
sap 2/2/2:200 endpoint "x" create
exit
spoke-sdp 3:300 endpoint "y" create
precedence primary
revert-time 0
exit
spoke-sdp 6:600 endpoint "y" create
precedence 0
exit
no shutdown
----------------------------------------------
*A:ALA-T-PE2>config>service>epipe#
S-PE1: Note that specifying the vc-switching parameter enables a VC cross-connect so the
service manager does not signal the VC label mapping immediately but will put this into passive
mode.
The following example displays the configuration:
*A:ALA-S-PE1>config>service>epipe# info
----------------------------------------------
...
spoke-sdp 2:200 create
exit
spoke-sdp 3:300 create
exit
no shutdown
----------------------------------------------
*A:ALA-S-PE1>config>service>epipe#