VLL Service Configuration Commands
Page 330 7750 SR OS Services Guide
config>service>cpipe>endpoint
config>service>epipe>endpoint
config>service>fpipe>endpoint
config>service>ipipe>endpoint
Description This command configures the time to wait before reverting back to the primary spoke SDP defined on
this service endpoint, after having failed over to a backup spoke SDP.
Parameters revert-time — Specify the time, in seconds, to wait before reverting to the primary SDP.
Values 0 — 600
Default 0
infinite — Causes the endpoint to be non-revertive.
standby-signaling-master
Syntax standby-signaling-master
no standby-signaling-master
Context config>service>vll>endpoint
Description When this command is enabled, the pseudowire standby bit (value 0x00000020) will be sent to T-
LDP peer for each spoke-sdp of the endpoint that is selected as a standby.
This command is mutually exclusive with a VLL mate SAP created on a mc-lag/mc-aps or ICB. It is
also mutually exclusive with vc-switching.
Default standby-signaling-master
interworking
Syntax interworking {frf-5}
no interworking
Context config>service>apipe
Description This command specifies the interworking function that should be applied for packets that ingress/
egress SAPs that are part of an Apipe service.
Interworking is applicable only when the two endpoints (i.e., the two SAPs or the SAP and the spoke-
sdp) are of different types. Also, there are limitations on the combinations of SAP type, vc-type, and
interworking values as shown in the following table.
SAP Type Allowed VC-Type Value Allowed Interworking Value
ATM VC
atm-vcc, atm-sdu none
fr-dlci Not Supported
FR DLCI
fr-dlci none