IES Interface Commands
Page 948 7750 SR OS Services Guide
max-advertisement-interval
Syntax max-advertisement-interval seconds
no max-advertisement-interval
Context config>service>ies>sub-if>grp-if>ipv6>router-ad
Description This command configures the maximum interval between sending router advertisement messages.
Default 900
Parameters seconds — Specifies the maximum interval in seconds between sending router advertisement
messages.
Values 900-1800
min-advertisement-interval
Syntax min-advertisement-interval seconds
no min-advertisement-interval
Context config>service>ies>sub-if>grp-if>ipv6>router-ad
Description This command configures the minimum interval between sending router advertisement messages.
Default 900
Parameters seconds — Specifies the minimum interval in seconds between sending router advertisement
messages.
Values 900-1350
mtu
Syntax mtu bytes
no mtu
Context config>service>ies>sub-if>grp-if>ipv6>router-ad
Description This command configures the MTU for the nodes to use to send packets on the link.
Default no mtu
Parameters bytes — Specifies the MTU for the nodes to use to send packets on the link.
Values 1280-9212