IES Service Configuration Commands
7750 SR OS Services Guide Page 955
link via IPCP extensions. This command is only applicable if the associated SAP/port is a PPP/
MLPPP interface with an IPCP encapsulation.
The no form of the command deletes either the specified primary DNS address, secondary DNS
address or both addresses from the IPCP extension peer-ip-address configuration.
Default no dns
Parameters ip-address — This parameter specifies a unicast IPv4 address for the primary DNS server to be
signaled to the far-end of the associate PPP/MLPPP link via IPCP extensions.
secondary ip-addressThis parameter specifies a unicast IPv4 address for the secondary DNS
server to be signaled to the far-end of the associate PPP/MLPPP link via IPCP extensions.
peer-ip-address
Syntax peer-ip-address ip-address
no peer-ip-address
Context config>service>ies>if>ipcp
Description This command defines the remote IP address to be assigned to the far-end of the associated PPP/
MLPPP link via IPCP extensions. This command is only applicable if the associated SAP/port is a
PPP/MLPPP interface with an IPCP encapsulation.
The no form of the command deletes the IPCP extension peer-ip-address configuration.
Default no peer-ip-address (0.0.0.0)
Parameters ip-address — Specifies a unicast IPv4 address to be signaled to the far-end of the associated PPP/
MLPPP link by IPCP extensions.
loopback
Syntax [no] loopback
Context config>service>ies>interface
Description This command specifies that the associated interface is a loopback interface that has no associated
physical interface. As a result, the associated IES interface cannot be bound to a SAP.
Note that you can configure an IES interface as a loopback interface by issuing the loopback
command instead of the sap command. The loopback flag cannot be set on an interface where a SAP
is already defined and a SAP cannot be defined on a loopback interface.