Chapter 5 Parameter Introductions
126
P5.08 Operating Timing T5
Range: 0.0~3600【10.0】
P5.09 Operating Timing T6
Range: 0.0~3600【10.0】
P5.10 Operating Timing T7
Range: 0.0~3600【10.0】
P5.11 Operating Timing T8
Range: 0.0~3600【10.0】
P5.12 Operating Timing T9
Range: 0.0~3600【10.0】
P5.13 Operating Timing T10
Range: 0.0~3600【10.0】
P5.14 Operating Timing T11
Range: 0.0~3600【10.0】
P5.15 Operating Timing T12
Range: 0.0~3600【10.0】
P5.16 Operating Timing T13
Range: 0.0~3600【10.0】
P5.17 Operating Timing T14
Range: 0.0~3600【10.0】
P5.18 Operating Timing T15
Range: 0.0~3600【10.0】
Note:
Configure the operating time of each PLC operating step. The range is
0.00~3600s (The time unit can be select by P5.03. The default time unit is second).
If the operating time of the step is set to 0, the inverter will skip the step and run
at the next step,
P5.19 Step T1 program operating setting
Range: 1 F~4 r【1F】
P5.20 Step T2 program operating setting
Range: 1 F~4 r【1F】
P5.21 Step T3 program operating setting
Range: 1 F~4 r【1F】
P5.22 Step T4 program operating setting
Range: 1 F~4 r【1F】
P5.23 Step T5 program operating setting
Range: 1 F~4 r【1F】
P5.24 Step T6 program operating setting
Range: 1 F~4 r【1F】
P5.25 Step T7 program operating setting
Range: 1 F~4 r【1F】
P5.26 Step T8 program operating setting
Range: 1 F~4 r【1F】
P5.27 Step T9 program operating setting
Range: 1 F~4 r【1F】
P5.28 Step T10 program operating setting
Range: 1 F~4 r【1F】
P5.29 Step T11 program operating setting
Range: 1 F~4 r【1F】
P5.30 Step T12 program operating setting
Range: 1 F~4 r【1F】
P5.31 Step T13 program operating setting
Range: 1 F~4 r【1F】
P5.32 Step T14 program operating setting
Range: 1 F~4 r【1F】
P5.33 Step T15 program operating setting
Range: 1 F~4 r【1F】
Note:
P5.19~P5.33 are used to set the direction and Acc/Dec time of each PLC operating
step. Total 8 kinds of combinations, which is shown in Table 5-5-1, could be
selected.