Chapter 4 Parameter Index
68
Function
code
Function Name Range of settings Default Change
MODBUS
Address
P4.25
Min output
impulse frequency
of DO
0.00~ Max Pulse frequency output of
DO
0.00kHz
○ 0519
P5: PLC Operating
Function
code
Function Name Range of settings Default Change
MODBUS
Address
P5.00
PLC Operating
mode
0: Single cycle 1
1: Single cycle 2 (holding final value)
2: Continuous operation
2 × 0600
P5.01
PLC restarting
mode selection
0: Restart from first step
1: Continue from the step where the
inverter stops
2: Continue to operate at the
frequency when the inverter stops
0 × 0601
P5.02
Saving PLC status
when power off
0: Not save
1: Save
0 × 0602
P5.03 Unit of step time
0: Second
1: Minute
0 × 0603
P5.04
Program Operating
Timing T1
0.1~3600 10.0 ○ 0604
P5.05
Program Operating
Timing T2
0.0~3600
10.0 ○ 0605
P5.06
Program Operating
Timing T3
10.0 ○ 0606
P5.07
Program Operating
Timing T4
10.0 ○ 0607
P5.08
Program Operating
Timing T5
10.0 ○ 0608
P5.09
Program Operating
Timing T6
10.0 ○ 0609
P5.10
Program Operating
Timing T7
10.0 ○ 060A
P5.11
Program Operating
Timing T8
10.0 ○ 060B
P5.12
Program Operating
Timing T9
10.0 ○ 060C
P5.13
Program Operating
Timing T10
10.0 ○ 060D
P5.14
Program Operating
Timing T11
10.0 ○ 060E
P5.15
Program Operating
Timing T12
10.0 ○ 060F