EasyManua.ls Logo

Alpha 6000 - P1: Start;Stop Control Parameters

Alpha 6000
219 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4 Parameter Index
55
Function
code
Function Name Range of settings Default Change
MODBUS
Address
P0.05
Keyboard
direction setting
0: Forward
1: Reverse
0 0105
P0.06 Basic Frequency
S2R4GB~3004GB/35R5PB :
0.10~650.0Hz
35R5GB/37R5PB or above:
0.10~400.0Hz
50.00Hz × 0106
P0.07
Maximum
output frequency
S2R4GB~3004GB/35R5PB :
MAX [50.00Hz, Upper limit
frequency, Reference frequency]
~650.0Hz
35R5GB/37R5PB or above:
MAX[50.00Hz, Upper limit
frequency,
Reference frequency] ~400.0Hz
50.00Hz × 0107
P0.08
Upper limit
frequency
MAX[Lower limit frequency ]~
Max frequency
50.00Hz × 0108
P0.09
Lower limit
frequency
0.00 ~ Upper limit frequency 0.00Hz × 0109
P0.10
Maximum
output voltage
110~480V
Rated
inverter
× 010A
P0.11
Step length of
digital encoder
regulation
0: Digital encoder integral
regulation
1~250* (0.01Hz|1rpm): Step
length of digital encoder regulation
0 × 010B
P0.12
V/F curves
setting
0: Constant torque curve
1: Torque-reducing curve1(2.0)
2: Torque-reducing curve2(1.5)
3: Torque-reducing curve3(1.2)
4: V/f Custom
(According to function code
P0.13~P0.18 )
0 × 010C
P0.13
V/F frequency
value F1
0.0~P0.15 10.00Hz × 010D
P0.14
V/F voltage
value V1
0.0~100.0% 20.0% × 010E
P0.15
V/F frequency
value F2
P0.13~P0.17 25.00Hz × 010F
P0.16
V/F voltage
value V2
0.0~100.0% 50.0% × 0110
P0.17
V/F frequency
value F3
P0.15~P0.06 40.00Hz × 0111
P0.18
V/F voltage
value V3
0~100.0% 80.0% × 0112

Table of Contents