Chapter 4 Parameter Index
55
Function
code
Function Name Range of settings Default Change
MODBUS
Address
P0.05
Keyboard
direction setting
0: Forward
1: Reverse
0 ○ 0105
P0.06 Basic Frequency
S2R4GB~3004GB/35R5PB :
0.10~650.0Hz
35R5GB/37R5PB or above:
0.10~400.0Hz
50.00Hz × 0106
P0.07
Maximum
output frequency
S2R4GB~3004GB/35R5PB :
MAX [50.00Hz, Upper limit
frequency, Reference frequency]
~650.0Hz
35R5GB/37R5PB or above:
MAX[50.00Hz, Upper limit
frequency,
Reference frequency] ~400.0Hz
50.00Hz × 0107
P0.08
Upper limit
frequency
MAX[Lower limit frequency ]~
Max frequency
50.00Hz × 0108
P0.09
Lower limit
frequency
0.00 ~ Upper limit frequency 0.00Hz × 0109
P0.10
Maximum
output voltage
110~480V
Rated
inverter
× 010A
P0.11
Step length of
digital encoder
regulation
0: Digital encoder integral
regulation
1~250* (0.01Hz|1rpm): Step
length of digital encoder regulation
0 × 010B
P0.12
V/F curves
setting
0: Constant torque curve
1: Torque-reducing curve1(2.0)
2: Torque-reducing curve2(1.5)
3: Torque-reducing curve3(1.2)
4: V/f Custom
(According to function code
P0.13~P0.18 )
0 × 010C
P0.13
V/F frequency
value F1
0.0~P0.15 10.00Hz × 010D
P0.14
V/F voltage
value V1
0.0~100.0% 20.0% × 010E
P0.15
V/F frequency
value F2
P0.13~P0.17 25.00Hz × 010F
P0.16
V/F voltage
value V2
0.0~100.0% 50.0% × 0110
P0.17
V/F frequency
value F3
P0.15~P0.06 40.00Hz × 0111
P0.18
V/F voltage
value V3
0~100.0% 80.0% × 0112