4-26 Marker Chapter 4 — Spectrum Analyzer
4-46 MS20xxA VNA Master UG 10580-00166 Rev. C
Marker 1 Reference On Off
This soft key selects whether Marker 1 is the reference for all six delta markers,
or whether each of the six reference markers has an associated delta marker.
When Marker 1 Reference is turned ON, Marker 1 is set to the current frequency.
The six delta markers are distributed evenly across the screen unless the
frequency is in the AM broadcast band. When the frequencies are in the AM
band, the delta markers are set to ±10.2 kHz, ±25 kHz, and ±75 kHz and the
marker table is also turned on.
Back
Returns to the previous menu.
Figure 4-16. Markers
Note
When using the up and down arrows, the active marker moves in steps defined by
the value entered using the Freq Step soft key.
When using the left or right arrow keys, the active marker moves by one division.