PARTNER Phone Administration Page 153
- Issue 1b (22 February 2010)IP Office PARTNER Version
System Maintenance: Remote Administration Password
15.3 Clearing a Backup Alarm
If an automatic backup fails, a backup failure alarm message appears instead of the system date and time at idle
extensions 10 and 11. After correcting the problem that caused the failure, you can clear the backup failure alarm.
To clear a backup alarm (ETR 18D/34D)
1.At a system administration extension (10 and 11); with the phone idle press Feature 0 0 followed by two presses
of Intercom 1. System Administration: is shown on the display.
2.Dial #123. The phone displays Clear Backup Alarm.
3.Press Enter to clear the backup alarm.
· Exit programming by pressing Feature 00. You can also exit programming mode by lifting the handset, then place
it back in the cradle.
To clear a backup alarm (1408/1416 Phone)
1.At either of the system administration telephones (extensions 10 and 11), with the phone idle press Admin.
2.Use the up or down arrow buttons to scroll the display to System Administration. When displayed, press
Select.
3.Use the up or down arrow buttons to scroll the display to System Parameters. When displayed, press
Select.
· Alternatively, dial # and the same code as used by ETR phones for system administration .
4.Use the up or down arrow buttons to scroll the display to Clear Backup Alarm. When displayed, press
Select.
5.To clear the alarm press Proceed.
· Exit programming by pressing PHONE/EXIT. Alternatively use the Back button to move to another menu.