7. Advanced
Image 7-79
The Transport Delay dialog box will be displayed.
Image 7-80
3. Push the cursor key or to select the radio buttons
4. Press ENTER to check the desired radio button
5. Press BACK to return to the Geom etry Edit menu.
How to adjust the Transport Delay manually?
1. Display the Tr ansport Delay dialog box (see procedure above)
Image 7-81
2. Use the cursor key or , the numeric keys on the RCU, or the local keypad, to edit and change the value of the Transport
Delay.
Note: The Transport Delay is by default set to 200.
The Transport Delay Range can be s e
t from 0 to 102 3.
Tip: When the transport delay needs to be adjusted In a multi channel setup, r st adjust the transport delay of all projectors
one by one, leave the projector with the maximum value, then set all other projectors to this maximum value.
3. Press BACK to return to the Geom etry Edit menu.