7. Advanced
Adjustment
Linear response
Sum
Intensity
Adj. value
Signal
0
1.0
1.5
0.5
512
1024
0
25% 50% 75% 100%
Image 7-170
GLD correction on Level 3
From the graph, you can clearly see the correction that has been done at:
•1.6%withinuence from 0% to 6.3%
14,1% with inuence from 3.6% to 25%
39.1% with inuence from 25% to 56.3%
76.6% with inuence from 56.3% to 100%
GLD correction on Hierarchy levels 1 and 3
Performing corrections on multiple hierarchies result in the sum of the different corrections. From the hierarchy 1 and hierarchy 3
corrections of the example above, the following nal GLD correctio
n is obtained.
Adjustment
Linear response
Sum
Intensity
Adj. value
Signal
0
1.0
1.5
0.5
512
1024
0
25% 50% 75% 100%
Image 7-171
GLD correction on Level 1 and 3
It is very important to perform the GLD alignment starting from Hierarchical level 1 and going up to Hierarchy
level 4.
208 R59770066 SIM 7Q SERIES 07/10/2013