/QUIET R / W 0...255
[ms]
Pause between level meters
transmission via CAN
/VU /RLS R / W 0...255
[ms/
dB]
Release time for Input / Output level
meters
/
INPTR
S
R / W -128...127
[dB]
Threshold for Input level meters
transmission via CAN
/
OUTT
RS
R / W -128...127
[dB]
Threshold for Output level meters
transmission via CAN
/LIMIT /RLS R / W 0...255
[ms/
dB]
Release time for Limiter level meters
/TRS R / W -128...127
[dB]
Threshold for Limiter level meters
transmission via CAN
/READ R Read out all level meters
/U R Read out all output voltages
/I R Read out all output currents
/Z R / W Read out all output impedance values
including MIN / MAX values that
occurred. Writing the channel name (A,
B) deletes MIN / MAX values.
Commands for Amplifier Temperature
Indication
/TEMP /ACT R -20...150
[°C]
Read out actual amp temperature
/HI R / W 20...150
[°C]
Threshold for thermal overload flag.
The flag is set as soon as the
temperature threshold is reached.
/HYS R / W 0...40 [°C] Hysteresis for thermal overload flag.
The flag is dele- ted, as soon as the
temperature falls below the thres- hold
minus hysteresis.
Commands for Audio Monitoring
IRIS-Net REMOTE AMPLIFIER | en 156
Bosch Security Systems B.V. User Manual 2017.05 | 3.20 | F.01U.119.956