/MONI R / W NONE,
RELAY,
IN_A,
OUT_A,
IN_B,
OUT_B
List of active elements for Audio
Monitoring. Input and output channels
can be monitored. RELAY switches
active channels onto the monitor bus.
Commands for DSP Parameters
/PRM /IDX100 R / W Read and write of DSP parameter
values via index numbers. For further
details please refer to "Descrip- tion of
General DSP Parameters" and/or "DSP
Parame- ter Index Table".
...
/IDX1A5 R / W
/LOAD R / W 1...8, F1 Load User Presets U01...U08 or Factory
Presets F01. Readout of preset data
loaded last. An asterisk '*' behind the
preset number indicates that values
have already been edited.
/SAVE W 1...8 Save User Preset U01...U08.
/TITLE R / W bis 16
Zeichen
Preset name
/DLYTEMP R / W -20.0...+60.
0 [°C]
Ambient temperature for the
calculation of delays with distance
values.
/DLYUNIT R / W MS, SAMP-
LES, FT, IN,
M, CM, US,
S
Delay unit. Delay values are read out
with the here set unit. When writing
delay values with /PRM/IDX... , the
stated unit is saved together with the
value.
Commands for Control Inputs / Control
Outputs
/CONTROL /IN1 /
STATE
R ON, OFF State of the control input
/ON /TIME R / W 0...10.0 [s] Delay / debounce time during
activation
IRIS-Net REMOTE AMPLIFIER | en 157
Bosch Security Systems B.V. User Manual 2017.05 | 3.20 | F.01U.119.956