Examples:
– /POWER/SWITCH ON ; switches amp's power on
– /TEMP/MODULE ? ; queries the remote control module temperature
– /TEMP/MODULE 65 ; reply to query: 65 °C
– /STFLAG/DEVICE/ACT ? ; queries operational state and error flags
– /STFLAG/ACT POWER,GLOBAL ; reply to query: Power is On, Global Error detected (Collected Error in external
CAN-devices)
– /STFLAG/GLOBAL ? ; queries for which external CAN-devices errors have been detected
– /STFLAG/GLOBAL 3-4 ; reply to query: Collected Error Flags on amps 3 and 4 are set
DSP PARAMETER INDEX TABLE
Input channel A or B
Index
Parameter Description Value Range Value Description
/IDX00 delay bypass 0 / 1 0 = ON, 1 = BYPASS
/IDX01 delay 1.68467...2000 ms
/IDX02 eq1 bypass 0 / 1 0 = ON, 1 = BYPASS
/IDX03 eq1 type 0...5 0 = peq, 1 = loshelv, 2 = hishelv, 3 = locut, 4 = hicut, 5 =
allpass
/IDX04 eq1 slope 0...2 0 = 0dB bypass, 1 = 6dB, 2 = 12dB
/IDX05 eq1frequency 20...20000 Hz
/IDX06 eq1 gain -18...12 dB
/IDX07 eq1 quality 0.4...40
/IDX08 eq2 bypass 0 / 1 0 = ON, 1 = BYPASS
/IDX09 eq2 type 0...5 0 = peq, 1 = loshelv, 2 = hishelv, 3 = locut, 4 = hicut, 5 =
allpass
/IDX0A eq2 slope 0...2 0=0dB bypass, 1=6dB, 2=12dB
/IDX0B eq2frequency 20...20000 Hz
/IDX0C eq2 gain -18...12 dB
/IDX0D eq2 quality 0.4...40
/IDX0E eq3 bypass 0 / 1 0 = ON, 1 = BYPASS
/IDX0F eq3 type 0...5 0 = peq, 1 = loshelv, 2 = hishelv, 3 = locut, 4 = hicut, 5 =
allpass
/IDX10 eq3 slope 0...2 0=0dB bypass, 1=6dB, 2=12dB
/IDX11 eq3frequency 20...20000 Hz
/IDX12 eq3 gain -18...12 dB
/IDX13 eq3 quality 0.4...40
/IDX14 eq4 bypass 0 / 1 0 = ON, 1 = BYPASS