/IDX15 eq4 type 0...5 0 = peq, 1 = loshelv, 2 = hishelv, 3 = locut, 4 = hicut, 5 =
allpass
/IDX16 eq4 slope 0...2 0=0dB bypass, 1=6dB, 2=12dB
/IDX17 eq4frequency 20...20000 Hz
/IDX18 eq4 gain -18...12 dB
/IDX19 eq4 quality 0.4...40
/IDX1A eq5 bypass 0 / 1 0 = ON, 1 = BYPASS
/IDX1B eq5 type 0...5 0 = peq, 1 = loshelv, 2 = hishelv, 3 = locut, 4 = hicut, 5 =
allpass
/IDX1C eq5 slope 0...2 0=0dB bypass, 1=6dB, 2=12dB
/IDX1D eq5frequency 20...20000 Hz
/IDX1E eq5 gain -18...12 dB
/IDX1F eq5 quality 0.4...40
/IDX20 eq6 bypass 0 / 1 0 = ON, 1 = BYPASS
/IDX21 eq6 type 0...5 0 = peq, 1 = loshelv, 2 = hishelv, 3 = locut, 4 = hicut, 5 =
allpass
/IDX22 eq6 slope 0...2 0=0dB bypass, 1=6dB, 2=12dB
/IDX23 eq6frequency 20...20000 Hz
/IDX24 eq6 gain -18...12 dB
/IDX25 eq6 quality 0.4...40
/IDX26 testgenerator enable 0 / 1 0 = OFF, 1 = ON
/IDX27 testgenerator level -128...+40 dB(u) at amplifier output, -128dB for Mute
/IDX28 not used
/IDX29 not used
/IDX2A route 0...2 0=A, 1=B, 2=A+B
/IDX2B 19kHz pilot notch filter 0 / 1 0=disable, 1=enable
Output channel A or B
Index
Parameter
Description
Value
Range
Value Description
/IDX00 level -128...+6 dB
/IDX01 mute 0 / 1 0 = ON, 1 = MUTE
/IDX02 route 0...3 0 = nothing, 1 = A, 2 = B, 3 = A+B
/IDX03 level trim -30...+6 dB
/IDX04 delay bypass 0 / 1 0 = ON, 1 = BYPASS
IRIS-Net REMOTE AMPLIFIER | en 228