2-24
Confidential
<When a toner cartridge in use is inserted after "Replace Toner" is displayed
by toner sensor detection
*1
>
A count value before changes is continuously indicated as a rotation rate of the develop
roller. Irrespective of the amount of toner, printing becomes disabled when the rotation rate
reaches the upper limit.
*1
Excluding a toner cartridge in use in which there is a little toner remained.
*2
The developing bias voltage is reset to the initial setting once when a toner cartridge in use
is inserted.
Corresponding counter, Setting value Operation
Counter of toner cartridge changes No count up
Page counter for each toner cartridge Continued
Coverage for each toner cartridge Continued
Developing bias voltage Reset (Initial setting)
*2
Note :
The discrimination between new and secondhand toner cartridges refers to the new
toner detection to be hereinafter described.