5-19
Confidential
Model without PCL/PS
<Operating Procedure>
(1) MFC7840W/7840N/7450/7440N/7340/7320
Press in order the 4 and 3 buttons in the initial stage of the maintenance mode.
DCP7045N/7040/7030
Press the or button. "MAINTENANCE 43" appears on the LCD, and then press the
OK button. "Manual Feed" appears on the LCD.
(2) Press the or button. The item to change is displayed on the LCD, and press the OK
button.
(3) Press the or button, or charge the parameter using the numeric keys. And press
the OK button. parameter value is confirmed.
<Function explanation>
Function Description Set value
Initial
value
Manual Feed Switching of the Manual Feed On/Off Off
Sleep Time Setting of the time until enter the SleepMode for
the engine
0 to 99 (minutes)
5
Auto I/F Time Switching of the I/F open time 1 to 99 (seconds) 5
P-Pos X-Offset Switching of the offset print position of the
landscape orientation
-500 to 500 (1/300dpi)
0
P-Pos Y-Offset Switching of the offset print position of the
portrait orientation
-500 to 500 (1/300dpi)
0
Function
Set value Problem
MANUAL FEED ON/OFF Configure the setting for the ON/OFF of the manual
paper feed. Effective for the print from the PC, or for
the print of the NetWorkConfig/TestPrint/Fontlist/
Configuration from the panel. When select the tray
on the PC, the setting becomes effective. And this
setting is ignored.
(Default : OFF)
RESOLUTION 300/600/1200 Configure the setting for the Resolution. Effective
only for the print from the PC. When set the
Resolution on the PC, the setting becomes effective.
And this setting is ignored.
(Default : 600)
TONER SAVE ON/OFF Configure the setting for the Toner Save Mode.
Effective for all print, and change the setting of the
Manu (Function). However, as for the Copy, this
setting becomes invalid. When set the Toner Save or
the PC, the setting becomes effective. And this
setting is ignored.
(Default : OFF)
DENSITY -6 to 6 Configure the setting for the Density. Effective for the
print from the PC, or for the print of the
NetWorkConfig/TestPrint/FontList/Configuration from
the panel. Link the setting of the Toner Save. Judge
the both setting, and decide the density. When set
the Density or the PC, the setting becomes effective.
And this setting is ignored.
(Default : 0)