D-23
Scanner
®
2000 microEFM Appendix D
Fluid Property Calculation
17 Crude Oil
18 Gasolines
19 Jet Fuels
20 Fuel Oils
21 Lube Oils
Tap Type Register
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Loc Tap Type
Loc (Pressure Tap Location)
0 Upstream
1 Downstream
Tap Type
0 Flange
1 Corner
2 D and D/2
3 Reserved
4 Reserved
5 Reserved
6 Reserved
7 Reserved
Flow Run 1 Calibration
Register
(Decimal)
Register
(Hex) Description
Data
Type Access Default
3200 C80 FR1 Calibration Type
1
U16 R/W 200
3201 C81 FR1 Nominal Flow Coefcient FP R/W 0.88
3203 C83 FR1 Coefcient Offset FP R/W 0.00
3205 C85 FR1 Flow Coefcient 1 FP R/W 0.88
3207 C87 FR1 Flow Coefcient 2 FP R/W 0.00
3209 C89 FR1 Flow Coefcient 3 FP R/W 0.00
3211 C8B FR1 Flow Coefcient 4 FP R/W 0.00
3213 C8D FR1 Flow Coefcient 5 FP R/W 0.00
3215 C8F FR1 Flow Coefcient 6 FP R/W 0.00
3217 C91 FR1 Flow Coefcient 7 FP R/W 0.00
3219 C93 FR1 Flow Coefcient 8 FP R/W 0.00
3221 C95 FR1 Flow Coefcient 9 FP R/W 0.00
3223 C97 FR1 Flow Coefcient 10 FP R/W 0.00
3225 C99 FR1 Flow Coefcient 11 FP R/W 0.00
3227 C9B FR1 Flow Coefcient 12 FP R/W 0.00
3229 C9D FR1 Flow Coefcient 13 FP R/W 0.00
3231 C9F FR1 Flow Coefcient 14 FP R/W 0.00

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cameron Scanner 2000 microEFM and is the answer not in the manual?

Cameron Scanner 2000 microEFM Specifications

General IconGeneral
BrandCameron
ModelScanner 2000 microEFM
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals