D-35
Scanner
®
2000 microEFM Appendix D
Interval/Daily/Event Pointer Registers
These registers provide an index of the last record that was stored in the log data. These values start at 1 and
increment with each newly created log. When the maximum number of records is reached, the pointer resets
to 1 and starts incrementing again.
Holding Registers (32-bit)
Register
(Decimal)
Register
(Hex) Description
Data
Type Access
7000 1B58 Interval Pointer FP RO
7001 1B59 Daily Pointer FP RO
7002 1B5A Event Counter FP RO
7003 1B5B Real Date FP RO
7004 1B5C Real Time FP RO
7005 1B5D Flow Run Alarms FP RO
7006 1B5E Flow Run Alarm Low FP RO
7007 1B5F Flow Run Alarm High FP RO
7008 1B60 Diagnostic 1 FP RO
7009 1B61 Diagnostic 2 FP RO
7010 1B62 Diagnostic 3 FP RO
7011 1B63 Diagnostic 4 FP RO
7012 1B64 Polling Index FP RO
7013 1B65 FR1 Grand Volume Total FP RO
7014 1B66 FR1 Instantaneous Flow Rate FP RO
7015 1B67 FR1 Daily Total FP RO
7016 1B68 FR1 Interval Total FP RO
7017 1B69 FR1 Polling Total FP RO
7018 1B6A FR1 Previous Day Total FP RO
7019 1B6B FR1 Previous Interval FP RO
7020 1B6C FR1 Previous Polling Total FP RO
7021 1B6D FR1 Grand Mass Total FP RO
7022 1B6E FR1 Instantanous Mass Flow Rate FP RO
7023 1B6F FR1 Daily Mass Total FP RO
7024 1B70 FR1 Interval Mass Total FP RO
7025 1B71 FR1 Polling Mass Total FP RO
7026 1B72 FR1 Previous Day Mass FP RO
7027 1B73 FR1 Previous Interval Mass FP RO
7028 1B74 FR1 Previous Polling Mass FP RO
7029 1B75 FR1 Grand Energy Total FP RO
7030 1B76 FR1 Instantaneous Energy Flow Rate FP RO
7031 1B77 FR1 Daily Energy Total FP RO
7032 1B78 FR1 Interval Energy Total FP RO
7033 1B79 FR1 Polling Energy Total FP RO
7034 1B7A FR1 Previous Day Energy FP RO
7035 1B7B FR1 Previous Interval Energy FP RO