Table 1.1—Scanner 2000 microEFM Specications
Electrical Safety
Classication
(Standard Scanner 2000
and Scanner 2000 with
Expansion Board)
Approved by CSA for US and Canada
Class I, Div. 1, Groups B, C, D (explosion-proof)
Class I, Div. 2, Groups A,B,C,D (non-sparking)
Type 4 enclosure, ANSI 12.27.01 single seal (0 to 3000 psi)
T6 temperature class
Approved by SIRA to
ATEX 07ATEX 1037X
IECEx SIR07.0022X
E
II 2 GD
c
Ex d IIC T6 (-40°C to +70°C) or Ex tD A21 IP68 T85°C (-40°C to +70°C)
GOST-R and GOST-K certied
Electrical Safety
Classication
(Scanner 2000 for
Foundation™ Fieldbus)
Approved by CSA for US and Canada
Class I, Div. 1, Groups B, C, D (explosion-proof)
Type 4 enclosure, ANSI 12.27.01 single seal (0 to 3000 psi)
T6 temperature class
Pressure Classication ASME pressure vessel code compliant, 0 to 3000 psi
(CRN 0F10472.5C)
Measurement Agency
Approvals
Approved by Measurement Canada for custody transfer, 0 to 1500 psi
(Approval No. AG-0557C)
Enclosure Cast aluminum, painted with epoxy and polyurethane
Weight 11.2 lb (5.08 kg), approximate
System Power Internal power supply
Battery pack, 2 “D” batteries in series, 7.2V, lithium
Battery life, 1-year, typical
External power supply (6 to 30 VDC) with internal battery backup (reverse
polarity protected)
Operating Temperature -40°C to 70°C (-40°F to 158°F)
LCD contrast is reduced below -30°C (-22°F)
LCD Display 8-digit top readout of values (7-segment characters)
6-digit bottom readout of scrolling parameters and associated engineering
units (11-segment characters for easy-to-read prompts)
View up to 12 user-dened parameters
View daily log data
User-selectable units of measurement
0.3” character height
Congurable scan parameters and duration
Adjustable contrast and update period
Keypad 3-key membrane switch
Password-protected security available

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cameron Scanner 2000 microEFM and is the answer not in the manual?

Cameron Scanner 2000 microEFM Specifications

General IconGeneral
BrandCameron
ModelScanner 2000 microEFM
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals