D-27
Scanner
®
2000 microEFM Appendix D
Holding Registers
Register
(Decimal)
Register
(Hex) Description Data Type Access
8108 1FAC FR1 Base Density FP RO
8110 1FAE FR1 Average Molecular Weight FP RO
8112 1FB0 FR1 Molar Fraction Sum FP RO
8114 1FB2 FR1 Mass Heating Value FP RO
8116 1FB4 FR1 Heating Value Volume Basis FP RO
8118 1FB6 FR1 Specic Gravity FP RO
8120 1FB8 FR1 Viscosity FP RO
8122 1FBA FR1 Isentropic Exponent FP RO
8124 1FBC FR1 Reynolds Number FP RO
8126 1FBE FR1 Calculation Parameter 1 FP RO
8128 1FC0 FR1 Calculation Parameter 2 FP RO
8130 1FC2 FR1 Calculation Parameter 3 FP RO
8132 1FC4 FR1 Calculation Parameter 4 FP RO
8134 1FC6 FR1 Calculation Parameter 5 FP RO
8136 1FC8 FR1 Calculation Parameter 6 FP RO
8138 1FCA FR1 Calculation Parameter 7 FP RO
8140 1FCC FR1 Calculation Parameter 8 FP RO
8142 1FCE FR1 Calculation Parameter 9 FP RO
8144 1FD0 FR1 Calculation Parameter 10 FP RO
8146 1FD2 FR1 Calculation Parameter 11 FP RO
8148 1FD4 FR1 Calculation Parameter 12 FP RO
8150 1FD6 FR1 Calculation Parameter 13 FP RO
8152 1FD8 FR1 Calculation Parameter 14 FP RO
8154 1FDA FR1 Calculation Parameter 15 FP RO
8156 1FDC FR1 Calculation Parameter 16 FP RO
8158 1FDE FR1 Grand Total [MCF] FP RO
8160 1FE0 FR1 Instantaneous Flow Rate [MCF] FP RO
8162 1FE2 FR1 Daily Total [MCF] FP RO
8164 1FE4 FR1 Interval Total [MCF] FP RO
8166 1FE6 FR1 Polling Total [MCF] FP RO
8168 1FE8 FR1 Previous Day [MCF] FP RO
8170 1FEA FR1 Previous Interval [MCF] FP RO
8172 1FEC FR1 Previous Polling Total [MCF] FP RO
8174 1FEE FR1 Grand Mass Total [LBM] FP RO
8176 1FF0 FR1 Instantaneous Mass Rate [LBM] FP RO
8178 1FF2 FR1 Daily Mass Total [LBM] FP RO
8180 1FF4 FR1 Interval Mass Total [LBM] FP RO
8182 1FF6 FR1 Polling Mass Total [LBM] FP RO
8184 1FF8 FR1 Previous Day Mass [LBM] FP RO
8186 1FFA FR1 Previous Interval Mass [LBM] FP RO
8188 1FFC FR1 Previous Polling Mass [LBM] FP RO

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cameron Scanner 2000 microEFM and is the answer not in the manual?

Cameron Scanner 2000 microEFM Specifications

General IconGeneral
BrandCameron
ModelScanner 2000 microEFM
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals